石膏恒温养护箱,砂浆养护箱,石膏恒温恒湿箱

石膏标准养护箱是专业石膏检测仪器,根据国家A新标准(石膏、砂浆,涂料,膨胀剂,保温材料,节能材料)养护设计而成.操作简单,全自动控制,可在任意气温和水温条件下,控制温度20℃±1,20℃-25℃之间进行试体养护,湿度控制在50%-80%之间,使用前务必仔细阅读说明书。并由专业实验人员操作,以避免操作不当引起的伤害。

  • 型号: HBY-30

  • 产品参数
  • 型号: HBY-30

 

石膏恒温养护箱,砂浆养护箱,石膏恒温恒湿箱是专业石膏检测仪器,根据国家A新标准(石膏、砂浆,涂料,膨胀剂,保温材料,节能材料)养护设计而成.操作简单,全自动控制,可在任意气温和水温条件下,控制温度20℃±1,20℃-25℃之间进行试体养护,湿度控制在50%-80%之间,使用前务必仔细阅读说明书。并由专业实验人员操作,以避免操作不当引起的伤害。

Gypsum standard curing box is a professional gypsum testing instrument. It is designed according to the national new standard A (gypsum, mortar, coating, expansion agent, thermal insulation material, energy-saving material). Simple operation, fully automatic control, can be used in any temperature and water temperature conditions. Under the control temperature of 20 ° C ± 1, 20 ° C -25 ° C for sample maintenance, humidity control between 50% -80%, be sure to read the instructions carefully before use. It is operated by professional experimenters to avoid injury caused by improper operation.

 

石膏恒温养护箱,砂浆养护箱,石膏恒温恒湿箱技术参数:

★电源: 220V

★箱内尺寸: 550× 550×1100(mm)

★恒温范围: 0--50℃可调

★恒湿范围: 35%--95%可调

★制冷功率: 145W

★加执功率: 300W

★加湿器功率: 15W

★去湿功率: 245W

★外型尺寸: 1200×1550×650 (mm)

重量:120kg

Gypsum standard maintenance box technical parameters:
★Power supply: 220V
★ Box size: 550 × 550 × 1100 (mm)
★ Constant temperature range: 0--50 °C adjustable
★ Constant humidity range: 35% - 95% adjustable
★ Refrigeration power: 145W
★Additional power: 300W
★ humidifier power: 15W
★Dehumidification power: 245W
★Dimensions: 1200×1550×650 (mm)
★ Weight: 120kg

 

石膏恒温养护箱,砂浆养护箱,石膏恒温恒湿箱操作规程:

①应将仪器置于通风干燥处,在环境温度2~38℃,相对湿度不大于85%,周围无强烈振动及强电磁场影响的室内使用。

②砂浆养护箱安放平稳后,应检查门开关是否灵活,电气、制冷等部件是否损坏。

③将箱内水箱加水至末层搁架以下,电热管以上2cm,把侧门打开将加湿器水箱内加注满蒸馏水,另把测温干湿盒内塑料球里注满水,并把纱布泡入水中。

④将电源插头插入具有良好接地的220V插座中,HBY-30按动电源开关,仪器自动进入工作状态。

⑤出厂时砂浆养护箱已编入标准设定程序,温度控制值为20.0℃±1.0℃,湿度控制值为95%±1.5%,无特殊要求,不能改变控制程序,否则将可能出现控温、控湿超出技术范围,如需要改变控制值数据,可按照控温仪说明书修改程序。

注意事项:

①电源电压波动超过规定使用范围,必须安装电源稳压器,否则将会损坏仪表及制冷机。

②电源接地一定要可靠,接地不良会对您的人身安全带来危险。

③经常检查加湿器、水箱,干湿盒内不要断水,盒内纱布要每月更换。

④非有关人员不能擅自改变控制程序数据,以免造成仪器失控及损坏仪器。

Gypsum standard maintenance box operating procedures:
1 The instrument should be placed in a ventilated and dry place, at an ambient temperature of 2 to 38 ° C, relative humidity of not more than 85%, indoor use without strong vibration and strong electromagnetic field.
2 After the mortar curing box is placed smoothly, check whether the door switch is flexible and whether the electrical, cooling and other components are damaged.
3 Add water to the tank inside the tank to the bottom of the shelf, 2cm above the electric heating tube, open the side door, fill the humidifier tank with distilled water, fill the plastic ball inside the temperature measuring wet box with water, and soak the gauze Into the water.
4 Insert the power plug into the 220V socket with good grounding. HBY-30 presses the power switch, and the instrument automatically enters the working state.
5The mortar maintenance box has been programmed into the standard setting procedure. The temperature control value is 20.0°C±1.0°C, the humidity control value is 95%±1.5%. There is no special requirement, and the control program cannot be changed. Otherwise, temperature control may occur. The humidity control is beyond the technical scope. If it is necessary to change the control value data, the program can be modified according to the temperature controller manual.
Precautions:
1 The power supply voltage fluctuates beyond the specified range of use, and the power supply regulator must be installed, otherwise the meter and the chiller will be damaged.
2 The power supply must be grounded reliably, and poor grounding can pose a danger to your personal safety.
3 Always check the humidifier and water tank. Do not cut off the water in the wet and dry box. The gauze in the box should be replaced every month.
4 Non-related personnel can not change the control program data without authorization, so as to avoid the instrument out of control and damage to the instrument.

 

石膏恒温养护箱,砂浆养护箱,石膏恒温恒湿箱常见故障排除方法:

①整机不工作:检查电源开关,保险丝是否损坏。

②不制冷:检查仪表是否显示制冷状态,检查压缩机过载保护器,起动器是否损坏,压缩机能正常运转而不制冷则可能是制冷剂泄漏。

③加湿器不加湿:检查加湿器内小风机是否工作,加湿器底座内水位是否过高,加湿器安放是否倾斜过大,雾化换能器是否干净。

④箱内温差大:检查风机是否工作,制冷指示灯亮而风机不工作,则风机损坏或保险丝坏。

⑤偶尔受外界电信号冲击,仪表出现数显失控,只需关闭电源开关或拔下电源插头,再重新开机,即能正常工作。

HBY-30 gypsum standard maintenance box common troubleshooting methods:
1 The whole machine does not work: Check the power switch and the fuse is damaged.
2 No cooling: Check whether the meter shows the cooling status, check the compressor overload protector, whether the starter is damaged, the compressor can run normally without cooling, it may be refrigerant leakage.
3 Humidifier does not humidify: Check whether the small fan in the humidifier works, whether the water level in the humidifier base is too high, whether the humidifier is tilted too much, and whether the atomizing transducer is clean.
4 The temperature difference inside the box is large: check whether the fan works, the cooling indicator light is on and the fan is not working, then the fan is damaged or the fuse is broken.
5 Occasionally, it is affected by external electric signals. The digital display of the instrument is out of control. Just turn off the power switch or unplug the power plug, then turn it back on, it will work normally.

 


石膏恒温养护箱,砂浆养护箱,石膏恒温恒湿箱

长按图片可保存到相册

图片加载中,请稍等 ...
长按图片保存/分享
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

石膏恒温养护箱,砂浆养护箱,石膏恒温恒湿箱

立即询盘
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

推荐产品

上海荣计达仪器科技有限公司

电话:021-61997300

传真:021-34795918

邮箱:289239104@qq.com

地址:上海市闵行区浦江镇联胜路189号 

邮编:201112 

图片展示

版权所有:上海荣计达仪器科技有限   公司地址:上海市闵行区浦江镇联胜路189号 邮编:201112   沪ICP备11009963号