持粘力试验仪、持粘性检测仪

持粘性测试仪主要适用于压敏胶粘带、医用贴剂、不干胶标签、保护膜等产品进行持粘性测试试验。

  • 型号: CNX-3

  • 产品参数
  • 型号: CNX-3

 

 

持粘力试验仪持粘性检测仪主要适用于压敏胶粘带、医用贴剂、不干胶标签、保护膜等产品进行持粘性测试试验。使用前务必仔细阅读说明书。并由专业实验人员操作,以避免操作不当引起的伤害。如需了解更多资料请与我公司客服人员联系。

The working principle of the viscous tester: the test plate with the sample attached is vertically hung on the test frame, the weight of the specified weight is suspended at the lower end, the displacement of the sample is dragged after a certain time, or the sample is completely detached. Time to characterize the ability of the adhesive tape to resist dragging. It is suitable for pressure sensitive adhesive tape, medical patch, self-adhesive label, protective film, plaster, Babu paste and other products for adhesive test.

 

持粘力试验仪持粘性检测仪工作原理:把贴有试样的试验板垂直吊挂在试验架上,下端悬挂规定重量的砝码,用一定的时间后试样粘拖的位移量,或试样完全脱离的时间来表征胶粘带抵抗拉拖的能力。适用于压敏胶粘带、医用贴剂、不干胶标签、保护膜、膏药、巴布膏等产品进行持粘性测试试验。

The working principle of the viscous tester: the test plate with the sample attached is vertically hung on the test frame, the weight of the specified weight is suspended at the lower end, the displacement of the sample is dragged after a certain time, or the sample is completely detached. Time to characterize the ability of the adhesive tape to resist dragging. It is suitable for pressure sensitive adhesive tape, medical patch, self-adhesive label, protective film, plaster, Babu paste and other products for adhesive test.

 

持粘力试验仪持粘性检测仪技术参数:

标准压辊:2000g±50g

砝码:1000g±10g(含加载板重量)

试验板:120mm(L)×60mm(W)×1.5mm(D)

计时范围:0—100h(标准配置)  0—10000h(可选)

工位数:3件、5件(可选)

外形尺寸:360mm×240mm×420mm

电源:AC 220V  50Hz

重量:11kg

Holding the viscosity tester technical parameters:
★ Standard pressure roller: 2000g ± 50g
★ weight: 1000g ± 10g (including loading plate weight)
★Test board: 120mm (L) × 60mm (W) × 1.5mm (D)
★ Timing range: 0—100h (standard configuration) 0—10000h (optional)
★Working position: 3 pieces, 5 pieces (optional)
★Dimensions: 360mm × 240mm × 420mm
★Power supply: AC 220V 50Hz
★ Weight: 11kg

 

持粘力试验仪持粘性检测仪使用方法:
水平放置仪器,打开电源开关,并将砝码放置在吊架下方槽内。
除去胶粘带试卷A外层的3~5 圈胶粘带后,以约300 mm/min的速率解开试样卷(对片状试样也以同样速率揭去其隔离层),每隔200mm左右,在胶粘带中部裁取宽25 mm,长约100 mm的试样。除非另有规定,每组试样的数量不少于三个。
用擦拭材料沾清洗剂擦洗试验板和加载板,然后用干净的纱布将其仔细擦干,如此反复清洗三次。以上,直至板的工作面经目视检查达到清洁为止。清洗以后,不得用手或其他物体接触板的工作面。
在温度23℃±2℃,相对湿度65%±5%的条件下,按图2规定的尺寸,将试样平行于板的纵向粘贴在紧挨着的试验板和加载板的中部。用压辊以约300 mm/min的速度在试样上滚压。注意滚压时,只能用产生于压辊质量的力,施加于试样上。滚压的次数可根据具体产品情况加以规定,如无规定,则往复滚压三次。
试样在板上粘贴后,应在温度 23℃±2℃,相对湿度 65%±5%的条件下放置20 min。然后将试验板垂直固定在试验架上,轻轻把砝码连接到加载板上。整个试验架置于已调整到所要求的试验环境下或试验箱内。
持粘性测试仪按开始键开始计时。
到达规定时间后,卸去重物。用带分度的放大镜测出试样下滑的位移量,精确至0.1mm;或者记录试样从试验板上脱落的时间(常用方法)。时间数大于等于1h的,以min为单位,小于1h的以s为单位。

 

How to use the sticky tester:
★ Place the instrument horizontally, turn on the power switch, and place the weight in the slot below the hanger.
★ After removing the 3 to 5 ring adhesive tape on the outer layer of the adhesive tape test A, unwind the sample roll at a rate of about 300 mm/min (the release layer is also peeled off at the same rate for the sheet sample). A sample with a width of 25 mm and a length of about 100 mm was cut in the middle of the adhesive tape at a distance of about 200 mm. Unless otherwise specified, the number of samples per group is not less than three.
★ Wipe the test board and the loading plate with a wiping material and a cleaning agent, then dry it carefully with a clean gauze, and wash it three times. Above, until the working surface of the board is visually inspected and cleaned. After cleaning, do not touch the working surface of the board with your hands or other objects.

★ At a temperature of 23 ° C ± 2 ° C, relative humidity of 65% ± 5%, according to the size specified in Figure 2, the sample is pasted parallel to the longitudinal direction of the plate in the middle of the test plate and the loading plate next to each other. The sample was rolled at a speed of about 300 mm/min with a press roll. Note that when rolling, it can only be applied to the specimen with the force generated from the quality of the press roll. The number of rolling can be specified according to the specific product conditions. If there is no regulation, the rolling is repeated three times.
★ After the sample is pasted on the board, it should be placed at a temperature of 23 °C ± 2 ° C and a relative humidity of 65% ± 5% for 20 min. The test plate is then mounted vertically on the test stand and the weight is gently attached to the load plate. The entire test rack is placed in the required test environment or in the test chamber.
★ Hold the viscosity tester and press the start button to start timing.
★ After reaching the specified time, remove the heavy objects. Use a graduated magnifying glass to measure the amount of displacement of the sample to the nearest 0.1 mm; or record the time the sample has fallen off the test plate (common method). The number of times is greater than or equal to 1h, in min, and less than 1h in s.


持粘力试验仪持粘性检测仪标准配置:主机、砝码3个、实验板6只、标准压辊一个

Standard configuration of the adhesive tester: 3 mainframes, weights, 6 experimental plates, 1 standard press roll


持粘力试验仪、持粘性检测仪

长按图片可保存到相册

图片加载中,请稍等 ...
长按图片保存/分享
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

持粘力试验仪、持粘性检测仪

立即询盘
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

推荐产品

上海荣计达仪器科技有限公司

电话:021-61997300

传真:021-34795918

邮箱:289239104@qq.com

地址:上海市闵行区浦江镇联胜路189号 

邮编:201112 

图片展示

版权所有:上海荣计达仪器科技有限   公司地址:上海市闵行区浦江镇联胜路189号 邮编:201112   沪ICP备11009963号