混凝土养护室控制器

混凝土养护室控制器用数字仪表控制,空调外机制冷,控制器内置养护水槽,确保喷水温度控制在20度±2度,适用于各种水泥厂,试验室及建筑公路施工单位、科研、科质检单位对标准养护室的温度控制,具有操作方便,控制准确等优点。

  • 型号:BYS-20

  • 产品参数
  • 型号:BYS-20


 

一,混凝土养护室控制器产品简介:

全自动养护室控制仪用数字仪表控制,空调外机制冷,控制器内置养护水槽,确保喷水温度控制在20度±2度,适用于各种水泥厂,试验室及建筑公路施工单位、科研、科质检单位对标准养护室的温度控制,具有操作方便,控制准确等优点。

First, the automatic maintenance room control instrument product introduction:
The automatic maintenance room control instrument is controlled by digital instrument, the air conditioner is externally cooled, and the controller has a built-in maintenance sink to ensure that the spray water temperature is controlled at 20 degrees ± 2 degrees. It is suitable for various cement plants, laboratories and construction highway construction units, scientific research. The temperature control unit of the quality inspection unit has the advantages of convenient operation and accurate control.

 

二,混凝土养护室控制器技术参数:

控温范围: 10~40

控温精度: 20±2

控湿范围: ≥95%(相对湿度)

加热功率: 1.5kW/2.5 kW /3.5 kW(常规配置/二通道配置/三通道配置)

制冷功率: ≤2kW(用户需自己配备≤3匹单冷空调,不要遥控器,控制回路接入本控制仪)

加湿功率: 60W

电源电压: AC220V±22V

电源频率: 50 Hz±1Hz

Second, the technical parameters of the automatic maintenance room control instrument:
★ Temperature control range: 10~40°C
★ Temperature control accuracy: (20 ° C) ± 2 ° C
★Control humidity range: ≥95% (relative humidity)
★ Heating power: 1.5kW/2.5 kW / 3.5 kW (regular configuration / two-channel configuration / three-channel configuration)
★ Refrigeration power: ≤ 2kW (users need to have ≤ 3 single-cooled air conditioners themselves, do not use remote control, control loops are connected to the controller)
★ humidifying power: 60W
★Power supply voltage: AC220V±22V
★Power frequency: 50 Hz±1Hz

 

三,混凝土养护室控制器操作规程:

设备加电前应详细阅读说明书,检查水路电路安装无误,并开启水龙头,使加热罐加足水,而且把室内加热箱也加足水。

通电源,机器即按出厂设置运行。设置方法:如需设置温度控制值20±1,湿度控制值92±2%。即:

1)按住“设置”键约5S后,至显示湿度控制窗的右起A位闪烁,调至显示值为92。

2)按“设置”键,至显示温度控制上限控制窗的右起A位闪烁,按“▲”键修改该项参数,修改完毕后,再按“ ”键移位则第二位闪烁,修改完毕后,再按“ ”键移位则第三位闪烁,调至显示值为21.0。

3)按“设置”键,至显示温度控制下限控制窗的右起A位闪烁,修改完毕后,再按“ ”键移位则第三位闪烁,调至显示值为19.0后按“确认”键退出。

如果在冬天或夏天,只要选择单热或单冷工作即可,控制开关在面板上(开关上翘为开状态,开关下翘为关状态)。

如上限为21.0,下限为19.0,处于制冷状态时,温度下降到20.2时停止加热。

除特殊调试外,工作人员进标养室应关机。对冷凝器、喷头应定期清理积垢,以保证工作效率。使用一段时间后,或水槽、纱布沾上灰尘、油污等,应及时清洗和更换,否则会使湿度值偏高。

Third, the automatic maintenance room control instrument operating procedures:
★ Before the equipment is powered on, read the instructions in detail, check that the water circuit is installed correctly, and turn on the faucet to add enough water to the heating tank, and add enough water to the indoor heating box.
★ Pass the power supply, the machine will run according to the factory settings. Setting method: If you need to set the temperature control value 20±1°C, the humidity control value is 92±2%. which is:
(1) Press and hold the “Settings” button for about 5 seconds, until the right A bit of the display humidity control window flashes, and the display value is 92.
(2) Press the “Settings” button to flash the right A bit of the temperature control upper limit control window. Press “▲” to modify the parameter. After the modification, press the “ ” button to shift the second digit. After the modification is completed, press the “ ” button to shift and the third digit will flash, and the display value will be 21.0.

(3) Press the “Set” button until the right A bit of the display temperature control lower limit control window flashes. After the modification is completed, press the “ ” button to shift the third digit to flash. After the display value is 19.0, press “Confirm”. "The key exits.
★ If you choose single or single cold work in winter or summer, the control switch is on the panel (the switch is turned up and the switch is turned off).
★ If the upper limit is 21.0 ° C, the lower limit is 19.0 ° C. When it is in the cooling state, the heating is stopped when the temperature drops to 20.2 ° C.
★ In addition to special commissioning, the staff should be shut down in the standard room. The condenser and nozzle should be cleaned regularly to ensure working efficiency. After using for a period of time, or the sink, gauze dipped in dust, oil, etc., should be cleaned and replaced in time, otherwise the humidity value will be higher.

 

四,混凝土养护室控制器工作原理:

★温控:当养护室内的温度高于温控仪上限给定值时,控制仪输出制冷型号,空调外机工作,PVC管内制冷,便室内降温,反之温度低于温控仪的下限设定值时,温控仪输出加热信号,PVC管内加热使室内升温。

★温控:当养护室内湿低于控制值时,系统输出加湿信号,离子加湿器工作,当达到设定值时自动停止工作。

Fourth, the working principle of the automatic maintenance room control instrument:
★ Temperature control: When the temperature in the curing room is higher than the upper limit of the temperature controller, the control unit outputs the cooling model, the air conditioner works outside, the PVC tube is cooled, and the room is cooled. Otherwise, the temperature is lower than the lower limit setting of the temperature controller. When the value is reached, the temperature controller outputs a heating signal, and the heating inside the PVC tube causes the room to heat up.
★ Temperature control: When the humidity in the maintenance room is lower than the control value, the system outputs the humidification signal, and the ion humidifier works, and stops automatically when the set value is reached.

 

五,混凝土养护室控制器安装:

将主机放于干燥、通风、周围无可燃物的位置,电源线,连接主机上的空调外机与冷热风机上的制冷铜管,将湿度探头安装于PVC管道与地面之间位置并固定好。养护室上方用PVC管四周接通,APVC管与制冷内机,离子加湿器相连即可。

Five, automatic maintenance room control instrument installation:
Place the main unit in a dry, ventilated, non-combustible location, power cord, connect the air conditioning unit on the main unit and the cooling copper tube on the hot and cold fan, and install the humidity probe between the PVC pipe and the ground and fix it. . The PVC pipe is connected around the top of the curing room. After the A, the PVC pipe is connected to the refrigeration internal machine and the ion humidifier.

 

六,混凝土养护室控制器使用方法:

本仪器出厂时已设定好的温度给定值无需在自行调整。

安装完毕后, 接通电源,开启仪表电源。

当环境温度高于设定值时,主机空调工作,PVC管制冷,使室内温度降温低至于设定温度。

当环境温度降于设定值时,PVC管内制热,使室内温度上升至设定温度

当湿度低于设定值时,主机驱动离子加湿器经管道向室内加湿,反之停止工作。

Six, the use of automatic maintenance room control instrument:
The temperature setpoint that has been set when the instrument is shipped from the factory does not need to be adjusted by itself.
After the installation is complete, turn on the power and turn on the meter.
When the ambient temperature is higher than the set value, the main air conditioner works, and the PVC pipe is cooled, so that the indoor temperature is lowered to a set temperature.
When the ambient temperature drops below the set value, the PVC pipe heats up, causing the room temperature to rise to the set temperature.
When the humidity is lower than the set value, the host drives the ion humidifier to humidify the room through the pipeline, and otherwise stops working.

 

七,混凝土养护室控制器结构

该控制仪由主机,冷热机,室内PVC管装置,离子加湿器组成。

Seven, automatic maintenance room control instrument structure
The controller consists of a host, a hot and cold machine, an indoor PVC pipe device, and an ion humidifier.

 

八,混凝土养护室控制器注意事项:

如夏季开启制冷开关时,必须关掉加热开关,反之冬季开启加热开关时必须关掉制冷开关。

控制仪外壳必须可靠接地,并安装漏电保护器。

加湿器严禁无水运行。

如温控仪显示混乱,必须安装稳压电源(3倍于主机功率)。

控制柜与空调外的位置之间距离控制在4米之内,以便于安装。

Eight, automatic maintenance room control instrument notes:
If the cooling switch is turned on in summer, the heating switch must be turned off. Otherwise, the cooling switch must be turned off when the heating switch is turned on in winter.
The control unit housing must be reliably grounded and a leakage protector installed.
The humidifier is strictly prohibited from running without water.
If the temperature controller shows confusion, a regulated power supply (3 times the host power) must be installed.
The distance between the control cabinet and the position outside the air conditioner is controlled within 4 meters for easy installation.

 

 


混凝土养护室控制器

长按图片可保存到相册

图片加载中,请稍等 ...
长按图片保存/分享
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

混凝土养护室控制器

立即询盘
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

推荐产品

上海荣计达仪器科技有限公司

电话:021-61997300

传真:021-34795918

邮箱:289239104@qq.com

地址:上海市闵行区浦江镇联胜路189号 

邮编:201112 

图片展示

版权所有:上海荣计达仪器科技有限   公司地址:上海市闵行区浦江镇联胜路189号 邮编:201112   沪ICP备11009963号