上海荣计达仪器科技有限公司

021-61997300 13761118616

累积点滴改进  迈向完美品质

www.rongjida.cn

图片展示
搜索

40B混凝土养护箱

40B混凝土养护箱是专业混凝土养护检测仪器,混凝土恒温恒湿养护箱是我公司根据相关标准新研制的一款升级产品。采用数显液晶显示器,控温数据准确,校准方便。

  • 型号:SHBY-40B

  • 产品参数
  • 型号:SHBY-40B

 

一,40B混凝土养护箱是专业混凝土养护检测仪器,混凝土恒温恒湿养护箱是我公司根据相关标准新研制的一款升级产品。采用数显液晶显示器,控温数据准确,校准方便。

First, the concrete constant temperature and humidity maintenance box is a professional concrete maintenance testing instrument. The concrete constant temperature and humidity maintenance box is an upgraded product newly developed by our company according to relevant standards. The digital display liquid crystal display has accurate temperature control data and convenient calibration.

 

二,40B混凝土养护箱主要技术参数

★控温精度±1℃       测温精度±0.5℃       箱内温度20℃

★加热功率600W        温差A型 <±1℃  B型 <±2℃

★整机噪声<65dB      工作电压220V±10%

★控湿精度±1%RH     相对湿度≥90%RH

★测湿精度±3%RH     频率50HZ

★压缩机功率136W      温湿传感器Pt100A级

★容积: 40B型550*550*1180mm

60B型920*650*1100mm

90B型1200*560*1400mm

Second, the main technical parameters of concrete constant temperature and humidity maintenance box
★ Temperature control accuracy ± 1 ° C Temperature measurement accuracy ± 0.5 ° C Temperature inside the box 20 ° C
★ Heating power 600W Temperature difference type A <±1°C Type B <±2°C
★The whole machine noise <65dB working voltage 220V±10%
★ humidity control accuracy ± 1% RH relative humidity ≥ 90% RH
★Measurement humidity accuracy ±3%RH Frequency 50HZ
★Compressor power 136W temperature and humidity sensor Pt100A level
★ Volume: 40B type 550*550*1180mm
60B type 920*650*1100mm
90B type 1200*560*1400mm

 

三,40B混凝土养护箱注意事项:

★电源电压波动超过规定使用范围,必须安装电源稳压器,否则将会损坏仪表及制冷机。

★电源接地一定要可靠,接地不良会对您的人身安全带来危险。

★经常检查加湿器、水箱,干湿盒内不要断水,盒内纱布要每月更换。

★非有关人员不能擅自改变控制程序数据,以免造成仪器失控及损坏仪器。

Third, the concrete constant temperature and humidity maintenance box Note:
★ If the power supply voltage fluctuates beyond the specified range, the power supply regulator must be installed, otherwise the meter and the refrigerator will be damaged.
★ The power supply grounding must be reliable, and poor grounding will bring danger to your personal safety.
★ Always check the humidifier and water tank. Do not cut off the water in the wet and dry box. The gauze in the box should be replaced every month.
★ Non-related personnel can not change the control program data without authorization, so as to avoid the instrument out of control and damage the instrument.

 

四,40B混凝土养护箱一般故障排除:

★整机不工作:检查电源开关,保险丝是否损坏。

★不制冷:检查仪表是否显示制冷状态,检查压缩机过载保护器,起动器是否损坏,压缩机能正常运转而不制冷则可能是制冷剂泄漏。

★加湿器不加湿:检查加湿器内小风机是否工作,加湿器底座内水位是否过高,加湿器安放是否倾斜过大,雾化换能器是否干净。

★箱内温差大:检查风机是否工作,制冷指示灯亮而风机不工作,则风机损坏或保险丝坏。

★偶尔受外界电信号冲击,仪表出现数显失控,只需关闭电源开关或拔下电源插头,再重新开机,即能正常工作。

Fourth, the concrete constant temperature and humidity maintenance box general troubleshooting:
★The whole machine does not work: Check the power switch and the fuse is damaged.
★ No cooling: Check if the meter shows the cooling status, check the compressor overload protector, whether the starter is damaged, the compressor can run normally without cooling, it may be refrigerant leakage.
★The humidifier is not humidified: Check whether the small fan in the humidifier works, whether the water level in the humidifier base is too high, whether the humidifier is tilted too much, and whether the atomizing transducer is clean.
★The temperature difference inside the box is large: check whether the fan works, the cooling indicator light is on and the fan is not working, then the fan is damaged or the fuse is broken.
★ Occasionally, it is affected by external electric signal. The digital display of the instrument is out of control. Just turn off the power switch or unplug the power plug, then turn it back on, it will work normally.

 

 

五,40B混凝土养护箱注意事项

★电源电压波动超过规定使用范围,必须安装电源稳压器,否则将会损坏仪表及制冷机。

★ 电源接地一定要可靠,接地不良会对您的人身安全带来危险。

★ 经常检查加湿器、水箱,干湿盒内不要断水,盒内纱布要每月更换。

★ 非有关人员不能擅自改变控制程序数据,以免造成仪器失控及损坏仪器。

Five, concrete constant temperature and humidity maintenance box precautions
★ If the power supply voltage fluctuates beyond the specified range, the power supply regulator must be installed, otherwise the meter and the refrigerator will be damaged.
★ The grounding of the power supply must be reliable. Poor grounding can pose a danger to your personal safety.
★ Always check the humidifier and water tank. Do not cut off the water in the wet and dry box. The gauze in the box should be replaced every month.
★ Non-related personnel can not change the control program data without authorization, so as to avoid the instrument out of control and damage the instrument.

 

六,40B混凝土养护箱一般故障排除

★ 整机不工作:检查电源开关,保险丝是否损坏。

★ 不制冷:检查仪表是否显示制冷状态,检查压缩机过载保护器,起动器是否损坏,压缩机能正常运转而不制冷则可能是制冷剂泄漏。

★加湿器不加湿:检查加湿器内小风机是否工作,加湿器底座内水位是否过高,加湿器安放是否倾斜过大,雾化换能器是否干净。

★ 箱内温差大:检查风机是否工作,制冷指示灯亮而风机不工作,则风机损坏或保险丝坏。

★ 偶尔受外界电信号冲击,仪表出现数显失控,只需关闭电源开关或拔下电源插头,再重新开机,即能正常工作。

恒温养护箱装箱单:主机壹台,搁板壹副,保险丝壹个,纱布壹块,说明书壹份,合格证壹份。

*注:如说明书与商品实物有出入,请以实物为准。

Sixth, concrete constant temperature and humidity maintenance box general troubleshooting
★ The whole machine does not work: Check the power switch and the fuse is damaged.
★ No cooling: Check if the meter shows the cooling status, check the compressor overload protector, whether the starter is damaged, the compressor can run normally without cooling, it may be refrigerant leakage.
★The humidifier is not humidified: Check whether the small fan in the humidifier works, whether the water level in the humidifier base is too high, whether the humidifier is tilted too much, and whether the atomizing transducer is clean.
★ The temperature difference inside the box is large: check whether the fan works, the cooling indicator light is on and the fan is not working, then the fan is damaged or the fuse is broken.
★ Occasionally, it is affected by external electric signal, and the instrument appears to be out of control. Just turn off the power switch or unplug the power plug, then turn it back on, it will work normally.
Constant temperature maintenance box packing list: main unit 壹台, shelf 壹, fuse 壹 one, gauze 壹 block, manual 壹, certificate 壹.
*Note: If there is any discrepancy between the manual and the actual product, please refer to the actual product.


40B混凝土养护箱

长按图片可保存到相册

图片加载中,请稍等 ...
长按图片保存/分享
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

40B混凝土养护箱

立即询盘
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

推荐产品

上海荣计达仪器科技有限公司

电话:021-61997300

传真:021-34795918

邮箱:289239104@qq.com

地址:上海市闵行区浦江镇联胜路189号 

邮编:201112 

图片展示

版权所有:上海荣计达仪器科技有限   公司地址:上海市闵行区浦江镇联胜路189号 邮编:201112   沪ICP备11009963号