上海荣计达仪器科技有限公司

021-61997300 13761118616

累积点滴改进  迈向完美品质

www.rongjida.cn

图片展示
搜索

水泥水化热试验仪

水泥水化热测定仪是水泥指标专业检测仪器,设备有自动恒温功能,自带制冷功能,无需外接恒温水浴,一体式设计,结构紧凑,操作方便。适用于中热硅酸盐水泥、低热矿渣硅酸盐水泥、普通硅酸盐水泥、矿渣硅酸盐水泥、火山灰硅酸盐水泥、粉煤灰硅酸盐水泥等的任何水化龄期的水化热测定。

  • 型号:SHR-650II

  • 产品参数
  • 型号:SHR-650II

 

水泥水化热试验仪产品简介:
水泥水化热测定仪是水泥指标专业检测仪器,设备有自动恒温功能,自带制冷功能,无需外接恒温水浴,一体式设计,结构紧凑,操作方便。适用于中热硅酸盐水泥、低热矿渣硅酸盐水泥、普通硅酸盐水泥、矿渣硅酸盐水泥、火山灰硅酸盐水泥、粉煤灰硅酸盐水泥等的任何水化龄期的水化热测定。

First, product introduction:
The cement hydration heat measuring instrument is a professional testing instrument for cement indicators. The equipment has automatic constant temperature function, self-contained cooling function, no external constant temperature water bath, integrated design, compact structure and convenient operation. Suitable for any hydration age water such as medium heat Portland cement, low heat slag Portland cement, ordinary Portland cement, slag Portland cement, volcanic ash Portland cement, fly ash Portland cement, etc. Heat determination. The total design, simple structure and accurate temperature control are indispensable test equipment for the cement laboratory.

二,水泥水化热试验仪技术参数:
★水槽温度:20℃±0.1℃
★真空瓶容积:约650ml
冷却速度为盛满比室温高5℃的水静置30分钟后≤0.001℃/min.℃
★酸液搅拌棒转速:500rpm
★功率:10W
★电压:AC220V
★转速:1500 rpm
★贝克曼差示温度计 ,示差范围:5~6℃  分度值:0.01℃
★外形尺寸:700×500×760mm
★仪器净重 :80kg
Second, technical parameters:
★Sink temperature: 20 °C ± 0.1 °C
★ Vacuum bottle volume: about 650ml
The cooling rate is ≤0.001 °C/min after standing for 30 minutes at room temperature 5 ° C higher than room temperature. °C
★ Acid stir bar speed: 500rpm
★ Power: 10W
★Voltage: AC220V
★Speed: 1500 rpm
★Beckmann differential thermometer, range of indication: 5~6°C Graduation value: 0.01°C
★Dimensions: 700 × 500 × 760mm
★ Instrument net weight: 80kg

三,水泥水化热试验仪使用方法
★在试验开始时,应将试验内筒从水槽内提升至水面以上位置固定好,打开试验内筒筒盖,将真空瓶、耐酸内衬、酸液搅拌棒放入内筒,将试验筒盖盖好,并拧紧蝶形螺母,密封筒盖,再将内筒慢慢沉入水中固定。
★将温度传感器插入水槽盖板上的插孔内并联接到控制仪,将其它各插件联接到控制仪相应插口。接通电源,检查接地是否可靠,打开控制仪电源开关。
★当水槽内水温高于20.1℃时,应慢慢地向水槽内放入冰块或冷水,待温度略底于20℃时即停止,此时,系统会自动将水温升至标准规定温度,并保持恒温。
★松开横梁上的锁紧手柄,将横梁转到使主轴与酸液搅拌棒在同一轴线上的位置,松开夹头,将搅拌棒向上提升装入夹头内,调整好酸液搅拌棒的高度位置后拧紧夹头,微调横梁转角,使酸液搅拌棒与筒盖上的孔同心,锁紧横梁上的锁紧手柄。装好贝克曼差示温度计和装料漏斗。
★按试验标准规定步骤完成操作。
★试验完成后,首先逐一关闭各部动作,再关掉总电源开关。拔下电源插头,再依次取出贝克曼差示温度计、装料漏斗、酸液搅拌棒、耐酸内衬等,清洗干净后妥善保存以备后用。试验内筒盖好后放置在筒座下面位置,盖好水槽活动盖板。
Third, the method of use
★ At the beginning of the test, the test inner cylinder should be lifted from the water tank to the water surface above the position. Open the test inner cylinder cover, put the vacuum bottle, acid-proof lining, acid stirring rod into the inner cylinder, and test the cylinder cover. Cover and tighten the wing nut, seal the tube cover, and then slowly sink the inner tube into the water to fix it.
★ Insert the temperature sensor into the jack on the sink cover and connect it to the control unit, and connect the other plugs to the corresponding socket of the control unit. Turn on the power, check if the grounding is reliable, and turn on the power switch of the controller.
★When the water temperature in the water tank is higher than 20.1 °C, slowly put ice cubes or cold water into the water tank, and stop when the temperature is slightly below 20 °C. At this time, the system will automatically raise the water temperature to the standard temperature. And keep the temperature constant.
★ Loosen the locking handle on the beam, turn the beam to the position where the main shaft and the acid stirring rod are on the same axis, loosen the chuck, lift the stirring rod upward into the chuck, and adjust the acid stirring rod. After the height position, tighten the chuck and fine-tune the corner of the beam so that the acid stir bar is concentric with the hole in the cylinder cover and lock the locking handle on the beam. Install the Beckman differential thermometer and the loading funnel.
★ Complete the operation according to the steps specified in the test standard.
★ After the test is completed, first turn off the actions of each part one by one, then turn off the main power switch. Unplug the power plug, and then remove the Beckman differential thermometer, charging funnel, acid stir bar, acid-resistant lining, etc., and then clean it for later use. After the inner cylinder is covered, place it under the cylinder seat and cover the water tank cover.

四,水泥水化热试验仪注意事项;
1.禁止在水槽内没有加水的情况下接通电源,进行操作,以防意外。
2.向水槽内加水前应先将试验内筒的筒盖盖好密封,并移至筒座底部的位置放好,防止加满水后再放入试验内筒时,溢流管来不及排水,大量的水从水槽上面外溢。
3.从主轴夹头上装卸酸液搅拌棒时应小心操作,防止酸液搅拌棒从高处跌落至真空瓶内,损坏真空瓶。
4.贝克曼温度计插入酸液部分及软木瓶塞表面应均匀涂覆石蜡等防酸涂料,试验前应仔细检查防酸涂层是否完好。
Fourth, matters needing attention;
1. It is forbidden to turn on the power and add water without adding water in the water tank to prevent accidents.
2. Before adding water to the water tank, the cylinder cover of the test inner cylinder should be sealed and moved to the bottom of the cylinder seat to prevent the overflow tube from being drained when the test tube is placed after the water is filled. A large amount of water overflows from the top of the sink.
3. Care should be taken when loading and unloading the acid stir bar from the spindle chuck to prevent the acid stir bar from falling from a high point into the vacuum bottle and damaging the vacuum bottle.
4. The surface of the Beckman thermometer inserted into the acid solution and the cork stopper should be evenly coated with anti-acid coating such as paraffin. The acid-proof coating should be carefully checked before the test.


水泥水化热试验仪

长按图片可保存到相册

图片加载中,请稍等 ...
长按图片保存/分享
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

推荐产品

上海荣计达仪器科技有限公司

电话:021-61997300

传真:021-34795918

邮箱:289239104@qq.com

地址:上海市闵行区浦江镇联胜路189号 

邮编:201112 

图片展示