上海荣计达仪器科技有限公司

021-61997300 13761118616

累积点滴改进  迈向完美品质

www.rongjida.cn

图片展示
搜索

硬质泡沫吸水率测定仪

硬质泡沫吸水率测定仪是根据国家标准GB8810-2005《硬质泡沫塑料吸水率检测》设计制造。具有使用简单、精确度高的特点,可被广泛使用于制造、科技的硬质泡沫塑料吸水率测试。

  • 型号: XSP

  • 产品参数
  • 型号: XSP


 

一,硬质泡沫吸水率测定仪产品简介:
是根据国家标准GB8810-2005《硬质泡沫塑料吸水率检测》设计制造。具有使用简单、精确度高的特点,可被广泛使用于制造、科技的硬质泡沫塑料吸水率测试。
First, the product introduction:
It is designed and manufactured according to the national standard GB8810-2005 "hard foam plastic water absorption rate detection". It has the characteristics of simple use and high precision, and can be widely used in the manufacturing and technology of rigid foam water absorption test.

二,硬质泡沫吸水率测定仪系统组成: 
硬质泡沫塑料吸水率测试系统是由:硬质泡沫塑料吸水率测试计算软件、试样装载专用网笼、测试样品水箱、硬质泡沫塑料质量测量仪、试样专用切片器、玻璃载片等六大部分组成。
Second, the system consists of
The rigid foam plastic water absorption test system is composed of: rigid foam plastic water absorption rate test calculation software, sample loading special net cage, test sample water tank, rigid foam plastic quality measuring instrument, sample special slicer, glass slide, etc. The six major components.

三,硬质泡沫吸水率测定仪技术参数:
★称量范围:5000g   测量精度:0.01g
★溢流箱规格:φ200*215mm
★网笼尺寸:Φ200*250mm 
★电压:200V
★外形尺寸:1000*600*800mm
★切片厚度0.1-0.4mm可调
★泡孔φ测试仪:*小计算孔径:0.1mm
Third, technical parameters
★Weighing range: 5000g Measurement accuracy: 0.01g
★Overflow box specification: φ200*215mm
★ Net cage size: Φ200*250mm
★Voltage: 200V
★Dimensions: 1000*600*800mm
★ slice thickness 0.1-0.4mm adjustable
★ Cell φ tester: * Small calculation aperture: 0.1mm

四,硬质泡沫吸水率测定仪使用方法:
★被测物尺寸:长度 150MM、宽度150mm、厚度 75mm;休积大于500cm3;
★环境温度:23±2℃      环境湿度:50±5﹪
★泡水液:蒸馏后至少放置 48小时的蒸馏水;
★将硬质泡沫切割成长 150MM宽 150毫米厚 75mm的正方形被测物。
★将试样放于天平上,称量干燥后的试样重量(m1),准确至 0.1g,并记录。
★悬挂网笼浸入蒸馏水中,除去悬挂网笼表层气泡,挂于天平的下称钩上,称其表现重量(m2),准确至 0.1g,并记录下来,记住后将悬挂网笼取下。
★将悬挂网笼2边套筒上的2个固定螺钉分别拧松,再将试样安放圆盘上并居中;将压棒下调压住试样,压棒2端紧扣试样,并旋紧2边套筒上的两个固定螺钉。
★将安装好试样的悬挂网笼重新浸入蒸馏水中,用软毛刷跟搅拌除去悬挂网笼和硬质泡沫表层气泡。
★浸泡96小时后,将盛有试样的悬挂网笼挂于天平下称钩上,称量其表现质量(m3),准确至0.1g,并记住下来 。
Fourth, the method of use
★Measurement object size: length 150MM, width 150mm, thickness 75mm; rest is not more than 500cm3;
★ Ambient temperature: 23±2°C Ambient humidity: 50±5%
★ soaking liquid: at least 48 hours of distilled water after distillation;
★ Cut the rigid foam into 150mm wide 150mm thick 75mm square measured object.
★ Place the sample on the balance and weigh the dried sample (m1) to the nearest 0.1g and record.
★The hanging net cage is immersed in distilled water to remove the air bubbles on the surface of the hanging net cage. It is hung on the lower hook of the balance, and its performance weight (m2) is called, accurate to 0.1g, and recorded, remember to take off the hanging net cage. .
★ Loosen the two fixing screws on the sleeve of the hanging cage 2, and place the sample on the disc and center it; press the pressure rod down to press the sample, press the end of the pressure rod 2, and rotate Tightening the two setscrews on the two side sleeves.
★ Re-dip the hanging net cage with the sample installed into the distilled water, and use a soft brush to stir and remove the hanging net cage and the foam bubbles on the surface of the rigid foam.
★ After soaking for 96 hours, hang the hanging net cage containing the sample on the hook under the balance, weigh the performance quality (m3), accurate to 0.1g, and remember it.

 

 

硬质泡沫吸水率测定仪切片器使用说明
硬质泡沫试样切片器是硬质泡沫塑料吸水率的一部分。
硬质泡沫试样切片器其主要结构有样品安放槽,样品厚度调节器,样品加紧螺丝,样品放置调节器的作用是:安放样品,并调节样品切片厚度。
Hard foam water absorption meter slicer instructions
The rigid foam sample slicer is part of the water absorption of the rigid foam.
The main structure of the rigid foam sample slicer is a sample placement groove, a sample thickness adjuster, a sample tightening screw, and a sample placement adjuster for: placing a sample and adjusting the thickness of the sample slice.

切片器技术参数:
1,切片器*小切片厚度:0.01-0.04mm,
2,试样尺寸:50*50*100mm
3,外形尺寸:150*150*130mm,
4,有效行程:25mm
5,整体重量:11KG 
 Slicer technical parameters:
1, slicer * small slice thickness: 0.01-0.04mm,
2, sample size: 50 * 50 * 100mm
3, Dimensions: 150*150*130mm,
4, effective stroke: 25mm
5, the overall weight: 11KG

使用方法:
1,将试件厚度调节器调节到25mm刻度处,松开样品加紧螺丝,将试件尺寸为50*50的样件放入安放槽内,旋紧样品夹紧螺丝压紧试件。
2,用切片刀沿切样器平台表面将多余的样品切除,为确保样品上部平整,可用切片厚度调节器调节出0.3mm,用切片刀将样品齐边。
3切片厚度调节器调节出所需切片厚度(顺时针为挤出样品,逆时针为样品退回样品安放槽),但应加上刀刃的厚度,切片刀刃厚度约为0.15-0.2mm,例如:切0.1mm厚度时应旋出0.3mm左右,再用切片机进行切片。  
  How to use:
1. Adjust the thickness adjuster of the test piece to the 25mm mark, loosen the sample tightening screw, put the sample piece with the test piece size of 50*50 into the mounting groove, and tighten the sample clamping screw to press the test piece.
2. Excavate the excess sample along the surface of the cutter platform with a slicing knife. To ensure that the upper part of the sample is flat, the slice thickness adjuster can be used to adjust 0.3 mm, and the sample is trimmed with a slicing knife.
The 3 slice thickness adjuster adjusts the required slice thickness (clockwise for the extruded sample and counterclockwise for the sample to return to the sample placement slot), but the thickness of the blade should be added. The sliced blade thickness is about 0.15-0.2mm, for example: cut When the thickness is 0.1mm, it should be rotated about 0.3mm, and then sliced with a microtome.

 

 


硬质泡沫吸水率测定仪

长按图片可保存到相册

图片加载中,请稍等 ...
长按图片保存/分享
询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

询盘

咨询表单:

  • 请输入验证码

咨询产品:


你还没有添加任何产品!

推荐产品

上海荣计达仪器科技有限公司

电话:021-61997300

传真:021-34795918

邮箱:289239104@qq.com

地址:上海市闵行区浦江镇联胜路189号 

邮编:201112 

图片展示

版权所有:上海荣计达仪器科技有限   公司地址:上海市闵行区浦江镇联胜路189号 邮编:201112   沪ICP备11009963号