上海荣计达仪器科技有限公司

咨询电话:137-6111-8616


直线式干燥时间测定仪

直线式干燥时间测定仪是检测仪器,是测量漆膜干燥时间的一种新型仪器,它对涂在表面上的色漆、清漆等各种涂料由流体变成稳定的薄膜,都能以描绘直线轨迹的形式、自动连续展现干燥过程各个阶段的状态,能直观的分析各阶段所用时间。

  • 型号: QGZ-A

  • 产品参数
  • 型号: QGZ-A

直线式干燥时间测定仪是**检测仪器,是测量漆膜干燥时间的一种新型仪器,它对涂在表面上的色漆、清漆等各种涂料由流体变成稳定的薄膜,都能以描绘直线轨迹的形式、自动连续展现干燥过程各个阶段的状态,能直观的分析各阶段所用时间。

The linear drying time tester is a testing instrument. It is a new type of instrument for measuring the drying time of paint films. It can change the paint on the surface, such as paints and varnishes, from fluid to a stable film. The form of the straight line trajectory, the state of each stage of the drying process is automatically and continuously displayed, and the time taken by each stage can be intuitively analyzed.


直线式干燥时间测定仪工作原理:

将制备好的漆膜试板放在试板托盘上,接通电源,电机通过丝杠带动划针做匀速直线运动(六个托盘每两个为一种时间即6h、12h、24h,全程为305mm)。由于漆膜随时间延长而逐渐干燥,因而划针在漆膜上的犁痕由宽变窄,由深变浅,以至A后划不出痕迹,从而显示出干燥情况的全过程。

Working principle of linear drying time measuring instrument:

Put the prepared paint film test plate on the test plate tray, turn on the power, and the motor drives the stylus through the screw to make a linear motion at a uniform speed. (Each two of the six trays is a time, that is, 6h, 12h, and 24h. The whole process is 305mm). As the paint film gradually dries over time, the plough marks on the paint film will be narrowed from width to depth, and shallower to deeper, so that no marks can be found after A, thus showing the whole process of drying.


直线式干燥时间测定仪技术参数:

★ 电源220V  50HZ

★测量误差 ±4%

★试验环境(GB1727—88)

★式样尺寸:316×24×3 mm

★直线轨迹周期:6 12 24 h

★划针行程:305mm

★电源220V 50HZ

★测量误差 ±4%

★外形尺寸:350*100*25mm

★重量:12kg

Technical parameters of linear drying time tester:

★ Power 220V 50HZ

★ Measurement error ± 4%

★ Test environment (GB1727—88)

★ Specification size: 316 × 24 × 3 mm

★ Straight track period: 6 12 24 h

★ Stroke stroke: 305mm

★ Power source 220V 50HZ

★ Measurement error ± 4%

★ Dimensions: 350 * 100 * 25mm

★ Weight: 12kg


直线式干燥时间测定仪使用说明:

★ 依涂膜的干燥快慢,选择适当的时间(6h、12h、24h)。

★将划针抬起,将大提扭向上抬起,推滑动座至左端,将如前所述制备好的试样放在托盘上,放下划针和大提扭。

★ 接通电源,按下电源开关,指示灯亮,再按下相应的分开关,指示灯亮,划针开始做匀速直线运动,到终点自动停止运动,而后将开关关闭。

★取下试板之前,在启始点做一记号,再分出各个干燥阶段,而后取下试板与时间